2. ACON,
PCON
19
ACON/PCON
output
PLC input side (* “n” indicates the first input address of each axis.)
DO on the ACON or PCON side and output data register
Remote I/O mode
Position/simplified
direct value mode
Half direct value
mode
Full direct value
mode
Remote I/O mode
2
PLC input
area
(bytes)
Number of
occupied bytes: 2
Number of
occupied bytes: 8
Number of
occupied bytes: 16
Number of
occupied bytes: 32
Number of
occupied bytes: 12
n, n+1
Port No.0 to 15
Port No.0 to 15
n+2, n+3
Current position
Current position
Current position
Occupied area
n+4, n+5
Completed
position No.
(simple alarm ID)
n+6, n+7
Status Signal
Command current
Command current
Current position
n+8, n+9
n+10, n+11
Current speed
Current speed
Command current
n+12, n+13
Alarm code
Alarm code
n+14, n+15
Status signal
n+16, n+17
n+18, n+19
n+20, n+21
n+22, n+23
n+24, n+25
n+26, n+27
n+28, n+29
Occupied area
n+30, n+31
Status signal
(Note) The Occupied area shows the domain to be occupied with the operation mode setting.
Therefore, this domain cannot be used for any other purpose. Also, exercise caution to avoid node
address duplication.