2. ACON,
PCON
15
8
1
2.4 Wiring
Example
2.4.1 Connection
Diagram
* Ethernet cable: Straight cable of category 5e or above, 100 m max
(Aluminum tape and braided double-shielded cable are recommended.)
(Note) Terminal processing is not required.
2.4.2 Connector Pin Layout
Pin number
Signal name
Signal abbreviation
1
Data trans
TD+
2
Data transmitted -
TD-
3
Data re
RD+
4 Not
used
5 Not
used
6
Data received -
RD-
7 Not
used
8 Not
used
Connector hood
Grounding pin for security
FG
RJ45 8-pin
modular connector
(Controller side)
PLC (EtherNet/IP master unit)
Ethernet
cable*
Ethernet cable*
Ethernet cable*
Other slaves
ACON/PCON
ACON/PCON
Hub
Summary of Contents for acon
Page 1: ...EtherNet IP IAI America Inc Operation Manual Second Edition ACON PCON SCON CA ...
Page 2: ......
Page 4: ......
Page 197: ...4 Appendix 191 PLC s IP Address Controller s IP Address ...
Page 214: ......
Page 215: ......