3. SCON-CA
169
3.7 I/O
Signal
Timings
When any of the control signal is turned ON to perform the operation of the actuator using the PLC's
sequence program, the response (status) is returned to the PLC. The maximum response time is expressed
using the following formula.
Maximum response time (msec)
䠙
Yt+Xt+3+ command processing time (operation time, etc.)
Yt: Master Stationslave transmission delay time
Xt: SlaveMaster Station Transmission Delay Time
Master Station For the master station
slave transmission delay (Yt) and slave
master station
transmission delay (Xt), refer to the Operation Manuals for the EtherNet/IP master unit and PLC installed in
the master unit.
Filed Network Transmission
Delay Time
Command
processing time
PLC sequence program
Control signal
Status signal
SCON
Control signal
Status signal
Master station
slave
station transmission
delay time (Yt)
Slave station
master
station delay time (Xt)