Requirements
Environment
The ambient temperature can affect cooling. Supplementary cooling can be necessary for a system that is
confined to a small, high-temperature space.
Utilities
Electric power
The system uses 3-phase alternating current (VAC) electricity. Some parts, such as valve solenoids and sensors,
use 24-volt direct current (VDC) electricity from a power supply in the electrical enclosure
WARNING
Some locations can be hazardous if the atmosphere contains gas, vapors, or dust in explosive
quantities. Refer to requirements from NFPA 70, National Electrical Code (NEC), the International
Electrotechnical Commission (IEC), and the Occupational Safety and Health Administration
(OSHA), as well as local codes for detailed information about environmental criteria.
Do not install this system in an environment where the temperature is freezing.
Ambient temperature
0.0°C to 40.0°C
(32°F to 104°F)
Altitude
(above mean sea level)
up to 2,000 m
(6,562 feet)
Operation temperature
5.0°C to 40.0°C
(41°F to 104°F)
Transportation and
storage temperature
-25.0°C to 55.0°C
(-13°F to 131°F)
Relative humidity
(noncondensing)
50% at 40.0°C (104°F)
90% at 20.0°C (68°F)
WARNING
Make sure that a line switch for disconnecting incoming electric power is installed near the power
supply to serve as a supply-voltage disconnecting or energy-isolating device.
WARNING
Work that requires opening the electrical enclosure or removing covers or panels from the EcoSift
unit must be done only by an approved technician.
WARNING
Installation, maintenance, and repairs to the electrical and plumbing systems must meet national
and local electrical and plumbing codes. This work must be done only by an approved technician.
Make sure that the primary feed protection device (circuit breaker or fuse) is sized to handle inrush
and steady-state current. Use a motor-start circuit breaker or an equivalent breaker if time-delayed,
high-inrush fuses are not approved by local or national codes.
50 Hz
60 Hz
400 VAC
480 VAC
3-phase at 40 FLA
3-phase at 34 FLA
Recommended breaker size: 60 A
Summary of Contents for EcoSift
Page 1: ...EcoSift Waterjet abrasive recycling system Operator Manual 809500 Revision 0 English ...
Page 12: ...SC 12 Safety and compliance Product stewardship Product stewardship Declaration of conformity ...
Page 14: ...SC 14 Safety and compliance Product stewardship Product stewardship ...
Page 16: ...SC 16 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 32: ...Terminology Terminology 32 EcoSift Operator Manual 809500 ...
Page 40: ...Product description Product description 40 EcoSift Operator Manual 809500 ...
Page 42: ...Options Options 42 EcoSift Operator Manual 809500 ...
Page 132: ...Troubleshooting Troubleshooting 132 EcoSift Operator Manual 809500 ...
Page 136: ...Specifications Specifications 136 EcoSift Operator Manual 809500 ...
Page 172: ...Installation Installation 172 EcoSift Operator Manual 809500 ...
Page 174: ...Technical drawings Technical drawings 174 EcoSift Operator Manual 809500 ...