P a g e
14 | 38
Chapter
II
System Description / Technical Data
UV systems
For disinfection of the water supplies a UV system should be installed. Ideally the Hydro
WELL
®
units
should be located in the incoming water main or after the site booster pump set where water storage
tanks are employed. The necessary radiation of 254 nm (wave length) is generated via application of
special mercury low-pressure UV lamps.
Hydro
WELL
®
Compact E systems comprise a high-quality stainless steel housing vessel. All
components are constructed and manufactured with respect to and in consideration of all current
standards as well as further technical specifications and corresponds to the latest state-of-the-art
technology.
Hydro
WELL
®
Compact E systems consist of the housing containing the UV lamp, with UV sensor to
monitor the transmission of UV light to ensure maximum exposure of the water within the housing and
a microprocessor control. For the most optimum monitoring of the unit performance a visual light
intensity display and NO or NC BMS contacts are available from the control box.
The unit has a doped quartz glass to prevent the formation of ozone and nitrate. An insert shim is
provided for the protection of the internal o-rings from the exposure to the UV light.
The unique flow path of the water should ensure shadow-free radiation of the water. Hydro
WELL
®
unit is flow directed and the inlet pipe is on the same side with the sensor and water will exit the unit
via outlet pipe on the opposite side.
Designs:
UV sensor
Fault message
Hydro
WELL
®
Compact 2E
YES
YES
Hydro
WELL
®
Compact 5E
YES
YES
Hydro
WELL
®
Compact 10E (7/16000)
YES
YES
Hydro
WELL
®
Compact 10E
YES
YES
Vertical installation of the UV housing vessel (in the horizontal pipeline) must be observed.
Water isolation valves should be fitted either side of the unit. If site require continuous water
supply to the building during maintenance works and no down time is required, then a suitable
by-pass should be fitted. By-pass should be suitably arranged to minimise dead legs.
Minimum of 500mm clearance above the unit is required for lamp exchange and cleaning
purposes. If a UV unit is to be installed around a booster pump set, it must be sited on the
outlet side of that pump. Some level of water flow through the UV chamber is required at all
times. This is to ensure th
at the UV lamp doesn’t overheat.
Suitable pre-filtration unit should be installed prior of the UV unit to minimize the level of
particulates in the water that may cause shadowing.
Summary of Contents for HYDROWELL Compact 10E
Page 16: ...P a g e 16 38 Reactor Dimensional drawing with parameters from technical data sheet...
Page 18: ...P a g e 18 38 Control Box Power switch ON OFF UV monitor Cable fittings...
Page 30: ...P a g e 30 38 Appendices 1 Installation Schematic UV Disinfection System...
Page 31: ...P a g e 31 38 Appendices 2 Wiring diagram HydroWELL 2 E 5 E and 10 E with sensor...