Page 24
7.3.4
Assembling of the side rails for the vortex
module wall
Vortex module walls consisting of 11 or more vortex module
rows are automatically equipped with side rails and self-tapping
screws.
The side rails have to be adapted to the right lenght by the
installer. The required lenght is the distance between the middle
of the lowest and the middle of the top vortex module.
The side rail is an u-section and made of stainless steel. It is
1.5mm thick. For the assembling the open side of the u-section
has to be attached to the latteral edge of the vortex module wall
(pos. 3). The lower end of the side rail is positioned in the middle
of the lowest vortex module. The lowest drilling (pos. 2) of the
side rail is used to screw in a self-tapping screw (M3.9X20). A
second self-tapping screw is used for the upper end of the side
rail.
The side rail for the other side of the vortex module wall has to
be assembled in the same way.