Performing Maintenance
OXiStop OXS-LID
en
Page 76 / 112
MoWa OXS-LID 3992764e en-us 2018-08-10.docx
2018-08-10
To replace the protective screen, proceed as follows:
1.
Switch off the unit/all components.
2.
Empty the OLF 5 bypass flow filtration unit, as described in chapter
"Replace the filter element on the OLF 5 bypass flow filtration
element" on page 71.
3.
Loosen the screw connection and remove protective strainer (CS.1)
between the two O-rings (CS.2).
4.
Dispose of protective strainer (CS.1) in an environmentally friendly
manner.
5.
Insert a new protective strainer (CS.1) between the two O-rings
(CS.2).
6.
Screw together the connector and fasten it tightly.
7.
The replacement of the protective screen is now complete.