Performing Maintenance
OXiStop OXS-LID
en
Page 89 / 112
MoWa OXS-LID 3992764e en-us 2018-08-10.docx
2018-08-10
4.
Now pull the sealing collar of diaphragm (6.1) carefully and evenly
over the threaded bolts.
Smooth down the sealing material under the sealing collar, working
carefully from the inside to the outside.
No sealant is permitted in the working area of the
diaphragms.
Sealant in the working area of the diaphragms leads to
malfunctions and damage to the unit.
5.
Put the diaphragm cover (6.2) on.
6.
Attach washers (6.5) to all threaded bolts and screw the nuts (6.6)
onto the threaded bolts by hand in a clockwise direction.
Always use new locknuts.
When locknuts are reused, they will no longer provide a
complete clamping effect.
7.
Tighten nuts (6.6) crosswise with a maximum torque of 8 Nm.
Example illustration: OXS-150/250LID:
8.
Mount the pipe of the valve block and tighten it firmly.
9.
Fill the unit as described in chapter "Filling the hydraulic tank with oil
(first filling/oil change)" on page 53.
10. Start up the unit and watch out for any leaks. Eliminate leakages
immediately.
11. The installation of the diaphragm is now complete.