Performing Maintenance
OXiStop OXS-LID
en
Page 69 / 112
MoWa OXS-LID 3992764e en-us 2018-08-10.docx
2018-08-10
Replace the filter element of the breather filter BF5/52 as follows:
1.
Screw the nut (6.46) and the washer (6.47) out of the breather filter
fully.
2.
Remove the cover (6.41).
3.
Remove used filter element (6.42) and dispose of it in an
environmentally correct manner.
4.
Insert the new filter element (6.42) and attach the cover (6.41) onto the
threaded bolt.
5.
Screw the nut (6.46) and the washer (6.47) onto the threaded bolt and
tighten the nut (6.46) with a maximum torque of 10 Nm.