Preparing installation/preparing tank
OXiStop OXS-LID
en
Page 37 / 112
MoWa OXS-LID 3992764e en-us 2018-08-10.docx
2018-08-10
Making the hydraulic connections to the unit
Connect the hydraulic tank to your hydraulic system at the corresponding
connections.
Electrically clamping the OLF 5 bypass flow filtration unit
DANGER
Exposed electrical components in the switch
cabinet
Risk of fatal injury from electrocution
►
Any work involving the electrical system may
only be done by a properly trained, certified
electrician.
Compare the voltage and frequency specifications on the unit name plate
with the existing network specifications.
Check the direction of rotation of the electric motor by switching it on briefly
(jog mode).
NOTICE
Incorrect phase sequence / rotation direction of the electric motor
The pump will be destroyed
►
In jog mode, check the direction of rotation of the electric motor.
►
A rotation direction arrow on the fan cover of the electric motor
identifies the correct direction of rotation.