Performing Maintenance
OXiStop OXS-LID
en
Page 73 / 112
MoWa OXS-LID 3992764e en-us 2018-08-10.docx
2018-08-10
9.
Fasten the dirt catch tray to the bottom
end of the filter element.
10. Lift the filter element with the cover and
dirt catch tray into the filter housing.
Observe correct placement of the O-ring
on the cover while doing so.
11
Fasten the cover with the tension clamp.
The tightening torque is a maximum of
5 Nm.
12. Tighten the drain plug (Drain) on the
connection part of the unit.
Switch on the OLF 5 bypass flow
filtration unit on.
Bleed air from the filter housing via the
measurement connection in the filter
cover.
13. If the bypass flow filtration unit has a
ContaminationSensor on the OLF 5
bypass flow filtration unit, replace the
protective screen – for details, refer to
chapter "Replace protective screen on
the OLF 5 bypass flow filtration unit " on
page 75.
14. Clean the suction strainer – for details,
refer to chapter "Clean/replace the
suction strainer on the OLF 5 bypass