Performing Maintenance
OXiStop OXS-LID
en
Page 75 / 112
MoWa OXS-LID 3992764e en-us 2018-08-10.docx
2018-08-10
Replace protective screen on the OLF 5 bypass flow filtration unit
NOTICE
Protective screen missing / operation without the protective screen
The ContaminationSensor clogged / blocked
►
Never operate the unit without a protective strainer.
►
Replace the protective strainer regularly.
A protective strainer is installed upstream from the ContaminationSensor to
protect it from blockage. Exchange the protective screen regularly depending
on the contamination level of the oil.
Item
Designation
CS.1
Protective strainer, 100 µm
CS.2
O-ring