Technical Data
FAM 15/30/50/70 ATEX
en(us)
Page 89 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
Technical Data
FAM 15
ATEX
FAM 30
ATEX
FAM 50
ATEX
FAM 70
ATEX
Filter size
OLF15
OLF 30
OLF 45
OLF 60
Filter element
1x
N15DMxxx
2x
N15DMxxx
3x
N15DMxxx
4x
N15DMxxx
Contents of the pressure
chamber
20 l
40 l
60 l
78 l
Contamination retention
capacity
according to ISO 4572
500 g
1000 g
1500 g
2000 g
Clogging indicator
VM 2 C.x
VM 2 C.x
VM 2 C.x
VM 2 C.x
Reaction pressure of the
differential contamination
display
2 bar
2 bar
2 bar
2 bar
Pump type
Gear pump Gear pump Gear pump Gear pump
Flow rate at 50 Hz
17 l/min
36 l/min
56 l/min
76 l/min
Operating pressure
4.5 bar
4.5 bar
4.5 bar
4.5 bar
Viscosity range
15 … 500
mm²/s
15 … 500
mm²/s
15 … 500
mm²/s
15 … 500
mm²/s
Electrical power
consumption
1900 W
2700 W
3200 W
5100 W
IP class
IP 55
IP 55
IP 55
IP 55
Length of the electrical
connection cable
10 m
10 m
10 m
10 m
Length of hoses
5 m
5 m
5 m
5 m
Hoses, material
NBR
NBR
NBR
NBR
Inlet / outlet
G1½ / G1
G1½ / G1
G1½ / G1
G1½ / G1
Material of sealings
NBR
NBR
NBR
NBR
Empty weight
640 kg
660 kg
680 kg
700 kg
Hydraulic fluid temperature 10 … 70°C 10 … 70°C 10 … 70°C 10 … 70°C
Ambient temperature
10 … 40°C 10 … 40°C 10 … 40°C 10 … 40°C
Typical dewatering speed
~ 1 l/h*
~ 1.7 l/h*
~ 2.2 l/h
~ 2.6 l/h
Minimum water content
100 ppm*
100 ppm*
100 ppm*
100 ppm*
Oil: HLP46; dewatering rate in particular dependent on fluid type, viscosity,