Performing maintenance / inspection
FAM 15/30/50/70 ATEX
en(us)
Page 61 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
Performing maintenance / inspection
DANGER
Risk of explosion
Danger of fatal injury
►
Perform all maintenance work outside of the
ATEX danger zone.
WARNING
Hydraulic systems are under pressure
Danger of bodily injury
►
The hydraulic system must be depressurized
before performing any work on the hydraulic
system.
Maintenance, repair and servicing work on the FAM must only be performed
by personnel who are both authorized and suitably trained for this purpose.
To prevent defects in the system, perform maintenance work regularly.
However, the intervals between inspections should not exceed a maximum of
one year.
When determining the inspection intervals, take the following conditions into
consideration.
Ambient conditions:
Set-up in the open
Wind,
rain,
sunlight
The operating conditions:
Degree of efficiency of the systems
Operator
errors
Manufacturer information in the technical documentation:
Mechanical and electrical service life
Relatively large changes in the total system:
For example, change in the zone division