Performing maintenance / inspection
FAM 15/30/50/70 ATEX
en(us)
Page 64 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
See page
Daily or
24 hours.
Weekly or
100 hours.
Monthly or
500 hours.
E
ver
y
si
x
months
or
2000
hour
s
Yearly or
4000 hour
s.
Replace oil, oil filter
X
Clean the vacuum pump of dirt and
dust.
Fan cover, fan wheels, air grille,
cooling fins, etc.
-
X
Check flame arrester.
(See operating instructions of
vacuum pump)
-
X
Check the measuring and security
technology for proper functioning.
(See operating instructions of
vacuum pump)
-
X
Change intake air filter, clean intake
strainer.
(See operating instructions of
vacuum pump)
-
X
Replacing the Air De-oiling Element
X
Emptying/Filling Pump
Check the filling level of the
reservoir to the seal chamber, and
top off if necessary.
X
Cleaning and inspecting the
ventilator hood
-
X
Fluid Filter
Change the filter element
(If this has not been required
earlier)
X
Oil mist separator
Changing the filter element
X
Electrics