Performing maintenance / inspection
FAM 15/30/50/70 ATEX
en(us)
Page 70 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
4.
(1) Have a suitable drip tray on hand to catch
the fluid.
(2) Open the drain fitting, and collect the
escaping fluid in the tray.
Once the housing has been completely
drained, close the drain fitting.
3.
Screw in the air bleed screw (x) by hand in a
clockwise direction and tighten it firmly using
a 10 mm Allen wrench.
4.
Release the housing tensioning clamps (1),
and remove them.
Remove the cover (a).
Remove the intermediate piece (b).