Error messages / troubleshooting
FAM 15/30/50/70 ATEX
en(us)
Page 49 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
Signal Inscription
Cause
Remedy
filled.
the FAM for leaks.
H12
Motor protection
switch Q2/Q3
Electric motor of
evacuation or vacuum
pump overloaded.
Switch on motor
protection in the
electronic control unit,
check operating
viscosity, drain fluid
from vacuum pump,
rinse and fill up with
fresh water.
H13
Dry-running
Evacuation
Pump
Too little medium is
being sucked into the
vacuum column.
Flow protection of the
dewatering pump (dry-
running protection)
Check suction strainer,
check suction pipe,
suction hose could be
attached to the floor.
Check vacuum pump,
and clean as required.
H14
Level switch
01/02/03
Level switch defective. Check level switch and
replace if necessary.
H15
Pressure V-
pump
Pressure in the
vacuum pump is too
high.
Exhaust filter cartridge
is used up.
Replace exhaust filter
cartridge (see operating
instructions of vacuum
pump).
Error
Cause
Remedy
Oil mist is coming out of
the exhaust line of the
vacuum pump.
Exhaust filter cartridge
is used up.
Replace exhaust filter
cartridge (see operating
instructions of vacuum
pump)
The vacuum pump has
an unusually high oil
consumption.
Exhaust filter cartridge
is used up.
Replace exhaust filter
cartridge (see operating
instructions of vacuum
pump)