Safety Information and Instructions
FAM 15/30/50/70 ATEX
en(us)
Page 19 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
Explosion protection as per ATEX 95
The water extraction units of the FluidAqua Mobile FAM-ATEX series satisfy
all the requirements of the new EU directive 94/9/EC, ATEX 95 applicable to
areas in which potentially explosive gas mixtures are likely to occur.
The designation of the explosion-proof ATEX-compliant unit is:
II 2G IIB3 T4 (+10°C<Ta<40°C)
This means that the FAM may be used only in accordance with:
E
E
q
q
u
u
i
i
p
p
m
m
e
e
n
n
t
t
g
g
r
r
o
o
u
u
p
p
II
Potentially explosive atmospheres in which
vapors or gas/air mixtures are likely to
occur.
Equipment category
2G
Equipment providing for a standard degree
of safety.
Designated for cases in which atmospheres
posing an explosion hazard can be
expected to occur very rarely and, if so,
only briefly.
Explosion hazard
subgroup
IIB3
Typical gases:
Town gas, acrylonitrile, ethylene, ethylene
oxide, ethylene glycol, hydrogen sulfide.
Ammonia, methane, ethane, propane, ethyl
alcohol, cyclohexane, n-butane, n-hexane.
Normal gap width: MESG
≥
0.65 mm
Ensure that vapors, gases or mists
occurring at the place of operation belong
to explosion groups IIA to IIB3.
Temperature class
T4
Maximum permissible surface temperature:
135°C