Error messages / troubleshooting
FAM 15/30/50/70 ATEX
en(us)
Page 59 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
[H14] Level switch 01/02(02/03)
Step
Description
Malfunction:
Level switch 01/02(02/03)
1.
Switch off the unit at the main switch.
2
Disconnect plug at the level sensor, and remove the level
sensor.
3.
Manually check the switching points on the level switch
-> a. Switching points are available. -> proceed to Step 5.
4.
-> b. Switching points not available. -> proceed to Step 6.
5.
Inspect the plug and the cable
to and in the control cabinet for
the PLC for proper functioning.
-> proceed to Step 7.
6.
Replace the level switch.
-> a. Function is available.
-> proceed to Step 8.
7.
-> b. Function not available.
-> proceed to Step 9.
8.
The PLC is faulty.
9.
Replace faulty parts.