Performing maintenance / inspection
FAM 15/30/50/70 ATEX
en(us)
Page 75 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
Clean the suction strainer.
NOTICE
Missing suction strainer
Pump is disrupted
►
Replace suction strainer
►
Clean the suction strainer regularly.
To protect the pump from coarse contamination particles and other foreign
bodies, a dirt trap with a strainer insert is fitted at the pump inlet.
This strainer insert must be cleaned at regular intervals, e.g. by flushing it
with solvent or blow-flushing it with compressed air.
1. Unscrew the screw plug (1)
counterclockwise with an open-
jaw wrench (50 mm).
2. Remove the strainer insert (3)
and clean it.
3. Check strainer insert (3) and
sealing ring (2) on the screw plug
for damage. Replace it if
necessary.
4. Insert the strainer insert (3).
5. Screw in the screw plug by hand,
and tighten it using the open-jaw
wrench (50 mm).
6. Check the suction strainer fitting
for leaks after commissioning.