Error messages / Troubleshooting
FluidAqua Mobil - FAM10/15-P
en(us)
Page 99 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
23. Oil filter contaminated -> replace oil filter
Cause:
The differential pressure display signal has been active
for 5 minutes. The FAM goes into the after-running
phase and switches off.
Remedy: Perform
the
following
steps:
Step
Description
1.
Message:
23. Oil filter contaminated -> replace oil filter
2.
Close all the locking features in the feed and return flow lines.
3.
Empty the filter housing via the drain ball valve.
4.
Replace the filter elements. For details, see page 81.
5.
Open all the locking features in the feed and return flow lines.
6.
Actuate ESC key and reset failure with the F3 key
7.
Start the unit by pressing the F1 key.
->a. The fault is repeated.
-> proceed to Step 9.
8.
->b. The fault is not repeated.
-> proceed to Step 13.
9.
Switch off the FAM and pull out the power plug.
Check clogging indicator, plug and supply line. Replace the
parts if necessary.
10. ->a. The test resulted in no errors. -> proceed to Step 12.
->b. The errors found were
eliminated.
-> proceed to Step 6.
12.
The PLC is defective -> contact the HYDAC Service
Department.
13.
The fault is repaired.