Starting up the FAM
FluidAqua Mobil - FAM10/15-P
en(us)
Page 43 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
Switching on the FAM
Move main switch to the "ON" position and wait until the "Fault" lamp lights
up briefly (lamp test) and the following start screen will appear after 30
seconds.
The most recently selected operating mode will be shown in the display.
Select an operating mode with heater in the presence of
viscosities
≥
350 mm²/s.
It is not mandatory that the heater be switched on in the
presence of lower viscosities, but it would contribute decisively
to the enhancement of dewatering performance.
Select the operating mode (OM) as described on page 57.
F1
F2
F3
F4
F1 = start FAM
F4 = switch to MENU1
Press the START key. The FAM begins with the starting phase:
The power unit control switches to the RF+D menu.
The vacuum pump starts up, the filling pump conveys and the vacuum
column is filled.
Set the required negative pressure in the vacuum column. See page
The evacuation pump is switched on and the starting period is finished
when the vacuum chamber is filled to the MAX filling level.
The FAM controller switches over to automatic operation.
Vent the filter housing.
Operating mode: Dewa Filtration
START
MENU1
Ready for operation, please press Start