Control panel basic (SIMATIC PANEL)
FluidAqua Mobil - FAM10/15-P
en(us)
Page 56 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
Selection Contamination (CONT.)
MENU1 -> Cont. -> ISO (example, can also be SAE or NAS depending on
sensor)
F1
F2
F3
F4
START =
Start
FAM
Display in operating status "Ready for operation" and
with the error message "Water content
≥
90%,
measurement with CS not possible".
STOP =
Stop
FAM
is displayed only in the operating status "Starting phase"
and "Automatic operation"
RESET
= Reset error messages
Is displayed only in the presence of faults
Display:
ISO: Nominal:
= The nominal value can be changed as follows:
4µ channel
= 2 … 25
6µ channel
= 1 … 24
14µ channel
= 0 … 23
ISO: Actual:
= Display of the current contamination at the FAM
inlet.
START
MENU1
ISO
tgt:
av:
Ready for operation. Please press Start
STOP RESET
4 µ
4 µ
6 µ
6 µ
14 µ
14 µ
20
18
18
16
15
14