Error messages / Troubleshooting
FluidAqua Mobil - FAM10/15-P
en(us)
Page 87 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
Error messages / Troubleshooting
NOTICE
Switch off the FAM at the main switch before opening the control
cabinet door
The main switch will be destroyed.
►
Do not open the control cabinet door if the main switch is not in OFF
position.
►
Do not use force to open the control cabinet door.
If an error occurs, the FAM goes into the status "Fault". This halts all
functions. The fault indicator lamp flashes.
To start the FAM, you must correct the error and acknowledge the error
message on the control panel.
An exception is the message "F2 fuse tripped", for which the indicator lamp
does not flash, the FAM will be switched off and the error message appears
on the display.
The fault messages are displayed only in the following screens:
Start
screen
RH+P (relative hu pressure)
T
(Temperature)
Cont.
(ContaminationSensor)
If a fault message is not shown in its entirety, then (...) will appear at the end
of the line on the display. The message can be displayed in its entirety with
the help of the
INS
key.
The fault messages that are relevant to the ContaminationSensor will only be
displayed on the "Cont" screen.
An exception is the message " CS-Zuförderp. Abgeschal.
CS1xxxStörung. Start 10 new attempts with Reset." This message will be
displayed on all screens.
The operator can switch into the different menus and operate a component in
the Manual menu necessary for the elimination of the fault.
No error messages are displayed in the Manual menu.
Summary of Contents for FluidAqua Mobil FAM 10-P
Page 123: ......