Error messages / Troubleshooting
FluidAqua Mobil - FAM10/15-P
en(us)
Page 93 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
11. / 12. / 14. / 15. Cable break
Cause:
Error 11. / 12. / 14. / 15.
The signal is immediately active after the lamp test
(except with AS temperature: 5 s), error message
flashes on the display, the FAM continues however to
run. The only exception: if the sensor controls the FAM
in the event of a cable break, the FAM will go into the
after-running phase and switch off.
Cause: Error
13.
The signal remains active for 5 seconds after the lamp
test. The charge pump for the CS is switched off
(because no water content is known and it can
therefore lead to incorrect measurements by the CS).
The FAM continues to run. The only exception: if the
sensor controls the FAM, the FAM will go into the after-
running phase and switch off.
Remedy: Perform
the
following
steps:
Step
Description
1. Message:
11. Cable break, heater ETS
12. Cable break, AS 1000 temperature
13. Cable break, AS 1000 water content
14. Cable break, CS
15. Cable break, pressure sensor HDA 4145, vacuum column
2.
Switch the FAM off at the main switch and unplug the power
connector.
3
Check the cables and plugs of the corresponding sensor up to
the PLC.
->a. The cable and plug are OK.
-> proceed to Step 9.
4.
->b. The cable and plug are not OK. -> proceed to Step 5.
5.
Check / replace the sensor
6.
Plug the power plug into the power outlet.
Switch on the FAM at the main switch and start operation by
pressing the F1 key.
->a. The fault is repeated.
-> proceed to Step 8.
7.
->b. The fault is not repeated.
-> proceed to Step 13.