FAM Set-up and Connection
FluidAqua Mobil - FAM10/15-P
en(us)
Page 38 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
Filling rotary vane vacuum pump
Remove the safety screw for the plug at
the level switch (1).
Remove the plug (2) for the level switch.
Unscrew the level switch (3) from the
vacuum pump.
Fill up with vacuum pump oil VE101
through the filling nozzle (4).
Check the oil level through the
inspection glass (5).
Fill up the vacuum pump oil no higher
than the MAX marking.
We recommend filling up to a level
between the MIN and MAX markings.
The suction strainer is re-mounted in
reverse order.
1
2
3
4
5
Check the fill level on the condensate separator
Check the condensate separator level before start-up.
During downtime (i.e. when the FAM is not in operation), the fill level must be
in the middle of the inspection glass.
If necessary, fill the condensate separator as described on page 76 in
Section Filling the condensate separator.