FluidAqua Mobil – FAM 10/15 +AS1000
Error messages
HYDAC Filtertechnik GmbH
en
Page 61 / 80
Motor Protection Switch
Y
Fault appears
again?
Failure repaired
No
Open the switch cabinet door, switch the motor protection switch and/or fuse back
on "I" that has tripped and check the setting of the motor protection switch and/or
the voltage capacity of the fuse in accordance with the motor type plate and/or the
h t
t
l t
1
Measure the electricity consumption of the engine
and/or of the heater whose motor protection switch or
fuse has tripped
Check the viscosity of the medium (only with motor pro-
tection switch)
Clean the tank of the water ring vacuum pump if neces-
Close switch cabinet door, main switch to "On", start FAM
Set the main switch to "Off"
Message:
Motor protection switch Q2, drain pump, tripped.
Motor protection switch Q3, vacuum pump, tripped.
Motor protection switch Q4, filling pump, tripped.
Motor protection switch Q5, CS pump, tripped.
Fuse element, heater
BEWA FAM10 3417360 en.doc
2008-06-06