Displayed
fault message
Cause
Remedy
see
Instructions for the
ContaminationSensor.
Instructions for the
ContaminationSensor.
Motor protection switch
Q2, drain pump,
tripped.
Electric motor of
evacuation pump over-
loaded
Switch on engine pro-
tection in the electric
control, check operat-
ing viscosity
Motor protection switch
Q3, vacuum pump,
tripped.
Electric motor of vac-
uum pump overloaded
Drain the fluid in the
tank, clean the tank,
refill
Motor protection switch
Q4, filling pump,
tripped.
Electric motor of filling
pump overloaded
Switch on engine pro-
tection in the electric
control, check operat-
ing viscosity
Motor protection switch
Q5, CS pump, tripped.
Electric motor of CS
pump overloaded
Switch on engine pro-
tection in the electric
control, check operat-
ing viscosity
Oil filter contaminated.
Please replace oil filter.
Maximum differential
pressure at the filter
reached
Changing the Filter
Element
Oil tank of rotary vane
vacuum pump empty.
Top up oil.
Oil level in the tank of
the rotary vane vacuum
pump too low
Top up oil
Oil tank of rotary vane
vacuum pump too full.
Please drain off oil.
Oil level in the tank of
the rotary vane vacuum
pump too high
Open ball faucet and
drain oil
Heater safety thermo-
stat triggered.
Oil temperature heater
too large, oil diffusion
too low through the
heater
Reset thermostat in the
head of the heater.
Remove the cover of
the heater to do so.
Check filling pump for
proper functioning
Fuse element, heater
Fuse has tripped
Call in an electrician
Supply voltage to FAM:
wrong phase se-
quence. Change phase
sequence.
incorrect phase se-
quence or phase se-
quence relay defective
Call in an electrician
Dry-running Evacuation
Pump.
too little medium is be-
ing pumped into the
vacuum column
check suction filter and
clean it if necessary,
check filling pump for
proper functioning,
check viscosity
Vacuum chamber over- Emergency Off Max
Check pressure in vac-
BEWA FAM10 3417360 en.doc