Dry run drain pump
Fault appears
again
Replacement of 2 phases on the mains plug, check mains volt-
age
Plug mains plug back in, switch on main switch
Switch off FAM, pull out mains plug
No
Y
es
Failure repaired
Pull out mains plug, check
mains cable and plug, re-
placing as necessary
Message:
Supply voltage to FAM: wrong phase
sequence. Change phase sequence.
Note:
If an engine is replaced at the same time, then the direction of rotation of the engine
in manual operation must be checked before the FAM is switched On.
BEWA FAM10 3417360 en.doc