FluidAqua Mobil – FAM 10/15 +AS1000
Error messages
HYDAC Filtertechnik GmbH
en
Page 49 / 80
Displayed
fault message
Cause
Remedy
see
CS conveyor
pump switched Off,
CS1xxx malfunction.
Start 10 new attempts
with Reset!
10x errors on the CS in
sequence
acknowledge the first
time this occurs and
restart, inform Service
Department if this oc-
curs again with a
week's time
flow at the FAM inlet
too low for 5 minutes
already. Please check
FAM inlet.
insufficient oil in the
vacuum column after
switch-on
check and open inlet
FAM outlet blocked.
Min. is not reached
Error, float switch of
rotary vane vacuum
pump at fill level Min/fill
level Overflow.
Float switch or cable
defective
Determine error and
replace defective part
Error, float switch of
vacuum tower at fill
level Min. and/or fill
level Max.
Float switch or cable
defective
Determine error and
replace defective part
Error, float switch of
water ring vacuum
pump at fill level Min/fill
level Overflow.
Float switch or cable
defective
Determine error and
replace defective part
Cable break, AS 1000
temperature
Cable break or AS is
defective
Determine error and
replace defective part
Cable break, AS 1000
water content
Cable break or AS is
defective
Determine error and
replace defective part
Cable break, CS.
Cable break or CS is
defective
Determine error and
replace defective part
No defined value from
CS.
For details, see Operat-
ing and Maintenance
Instructions for the
ContaminationSensor.
For details, see Operat-
ing and Maintenance
Instructions for the
ContaminationSensor.
No measured value
from CS. Check flow.
For details, see Operat-
ing and Maintenance
Instructions for the
ContaminationSensor.
For details, see Operat-
ing and Maintenance
Instructions for the
ContaminationSensor.
Malfunction CS flow too
low.
For details, see Operat-
ing and Maintenance
Instructions for the
ContaminationSensor.
For details, see Operat-
ing and Maintenance
Instructions for the
ContaminationSensor.
Fault, CS device error
For details, see Operat-
ing and Maintenance
For details, see Operat-
ing and Maintenance
BEWA FAM10 3417360 en.doc
2008-06-06