FluidAqua Mobil – FAM 10/15 +AS1000
Starting up the FAM
HYDAC Filtertechnik GmbH
en
Page 29 / 80
Shutting off the FAM
F1
F2
F3
F4
F1 = Start FAM
F2 = Stop
F3 = Reset (after malfunction)
F4 = Switch to MENU1
Automatic mode
Operating mode: D Filter
STOP
MENU1
Press the "STOP" key. Now the unit starts the run-down phase:
•
the vacuum pump and all filling pumps are switched off.
Exception: When the heater is switched on, a 60-second cooling phase inter-
venes during which only the heater is switched off.
It is not until this has run its course that the filling pumps are switched off. The
respective current operating status will be shown in the display.
•
The evacuation pump runs until the vacuum column is empty.
The run-down phase status is shown in the display
•
If the main screen from Section 0 appears on the display, then the after-running
phase has been completed and the FAM is ready for operation again.
•
Now the FAM can be switched off via the main switch.
BEWA FAM10 3417360 en.doc
2008-06-06