![HYDAC ELECTRONIC HLT 2100 Series Assembly Instructions Manual Download Page 35](http://html.mh-extra.com/html/hydac-electronic/hlt-2100-series/hlt-2100-series_assembly-instructions-manual_2191396035.webp)
Steckerbelegung [Pin Assignment]
Printed in the Federal Republic of Germany
HYDAC –ELECTRONICGMBH , All Rights Reserved
Stand:21.07.2010
Mat. Nr. 669792
Page 35 of 36
6.12 HLT 2100-R1-E51-ETC-… / HLT 2500-Lx-E51-ETC-… / HLT 2500-F1-E51-ETC-…
Signalausgang EtherCAT, Gerätebuchse M12x1, 4-pol. + Gerätestecker M12x1, 4-pol. + Gerätestecker M8, 4-pol.
Signal output EtherCAT, female connector M12x1, 4-pin + male connector M12x1, 4-pin + male connector M8, 4-pin
X1 PORT-IN / X3 PORT-OUT
Flanschdose M12x1-4 pol. D-kodiert /
Flange socket M12x1-4 pin D-coded
Pin 1
TxD+, Send /
transmitted data +
Pin 2
RxD+, Empfang /
received data +
Pin 3
TxD–, Sendedaten – /
transmitted data
–
Pin 4
RxD–, Empfangsdaten – /
received data
–
X2
Versorgung
/ Supply
Flanschstecker M8x1-4 pol. / M12x1-4 pol. A-coded
Flange connector M8x1-4 pin / M12x1-4 pol. A-coded
Pin 1
19 – 27 V DC
Pin 2
TR,
optional
Pin 3
GND, 0 V
Pin 4
TRWinProg–,
optional
Für die Versorgung sind paarweise verdrillte und geschirmte Kabel zu verwenden !
Shielded twisted pair cables must be used for the supply !
HLT 2500-F1
HLT 2100-R1 / HLT 2500-Lx