P/N 3053328_C 5-1
Reach-In
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
CARE AND CLEANING
Long life and satisfactory performance of any
equipment is dependent upon the care it receives.
To ensure long life, proper sanitation and minimum
maintenance costs, these merchandisers should be
thoroughly cleaned, all debris removed and the
interiors washed down, weekly.
Fan Plenum
To facilitate cleaning, the fan plenum is hinged and
also fastened with screws at each end. After cleaning be
sure the plenum is properly lowered into position and
that screws are reinstalled
or
producT
loss
will
resulT
due to improper refrigeration.
Always*Clear™ Glass
Wipe inside of glass with isopropyl alcohol and a
soft cloth. Allow surface to dry before closing door.
Use of other cleaners or abrasives may damage the
Always*Clear surface, and/or void the warranty. Refer
to manual that ships with doors.
Interior Surfaces
The interior surfaces may be cleaned with most
domestic detergents, ammonia based cleaners and
sanitizing solutions with no harm to the surface.
Exterior Surfaces
The exterior surfaces should be cleaned with a mild
detergent and warm water to protect and maintain
their attractive finish.
n
ever
use
abrasive
cleansers
or
scouring
pads
.
D
o
N
ot
U
se
:
•Abrasive cleansers and scouring pads, as these will
mar the finish.
• Coarse paper towels on coated glass.
•Ammonia-based cleaners on acrylic parts.
•Solvent, oil or acidic based cleaners on any interior
surfaces.
MAINTENANCE
Do NOT use HOT water on COLD glass surfaces.
This can cause the glass to shatter and could
result in personal injury. Allow glass fronts,
ends and service doors to warm before applying
hot water.
SHUT FANS OFF DURING
CLEANING PROCESS.
Always disconnect the electrical power
at the main disconnect when servicing or
replacing any electrical component. This
includes, but is not limited to, such items
as fans, heaters, thermostats and lights.