P/N 3053328_C 4-1
Reach-In
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
START UP / OPERATION
If a leak is detected, follow store safety procedures.
It is the store’s responsibility to have a written safety
procedures in place. The safety procedure must
comply with all applicable codes such as local fire
department’s codes.
At minimum, the following actions are required:
• Immediately evacuate all persons from the store, and
contact the local fire department to advise them that a
propane leak has occurred.
• Call Hussmann and/or a qualified service agent and
inform them that a propane sensor has detected the
presence of propane.
• Do not let any persons back into the store until
the qualified service technician has arrived and that
technician advises that it is safe to return to the store.
• The propane gas used in the unit has no odor. The
lack of smell does not indicate a lack of escaped gas.
• A hand-held propane leak detector (“sniffer”) should
be used before any repair and/or maintenance is
attempted. All repair parts must be identical models to
the ones they are replacing.
• No open flames, cigarettes or other possible sources
of ignition should be used inside the building where
the units are located until the qualified service
technician and/or local fire department determines
that all propane has been cleared from the area and
from the refrigeration systems.
Prior to Start-up Check List
• Is the case connected to its proper nameplate power
supply?
• Is there power on at the breaker panel?
• Are the water hand valves open?
• Is the cooling water system on and circulating water
through the condenser(s)?
• Are there any leaks from condenser water
connections? Clamps may need to be tightened.
• Are the doors properly torqued and self closing?
Check each door at the fully open position and at
1-inch open position.
• Do evaporator fans rotate freely? Are they plugged
in? (Inspect fans by lifting the deck pans in the bottom
of the cases; manually rotate each fan to confirm free
rotation and visually inspect that they are plugged
into the receptacles.)
• Is the water strainer clear of debris?
Starting up the case
• Ensure the water flow is on, and turn the disconnect
switch to the ON position.
The case(s) will start automatically within 4 minutes.
The controller will be activated and the case will begin
to cool down.
Possible hazardous condition. Follow
safety procedures outlined by store
safety management.