Once the desired output assignment is displayed, press the
ENTER key on the Hand-Held device or the SELECT
button on the Safe-NET display module to store the new
value to NV memory. The display will revert to cycling
between LGHT and the new value.
Note:
The Safe-NET system must be RESET for the new value to
take effect.
Assigning an output in error will result in unexpected case
operation.
Output assignments are labeled on the relay module.
Light output will default to ON.
ON/OFF control is by network command.
DEGR
The DEGR parameter determines the units in which the
Safe-NET display module presents temperature
information. The Safe-NET display module is capable of
displaying either degrees Fahrenheit or degrees Celsius.
Setting this parameter is done in the SETUP menu. After
navigating to the DEGR sub menu item, the display will
cycle between DEGR and the current setting. While the
setting is being displayed, press ENTER on the Hand-
Held device or press the SELECT button on the
Safe-NET display module to allow editing of the value.
When the Safe-NET display module begins flashing the
value, use the UP or DOWN arrow keys on the Hand-
Held device or the UP /DOWN buttons on the Safe-NET
display module to change the setting.
4-15
P/N 0461391A
Hussmann Corporation • Bridgeton, Missouri 63044-2483 U.S.A.
Safe-NET™
Menu Structure — LGHT
Menu Structure — DEGR