If the unit reverts to the default display due to either an
inactivity time-out or use of the escape button sequence,
pressing the SELECT button will advance to the next
top-level menu in sequence as shown above.
Once a top-level menu is displayed, the first sub menu
item and its associated value will be displayed after 1
second.
Pressing the SELECT button will move to the next top-
level menu in sequence and the submenu/value cycling will
repeat for the new top-level menu.
2. After using the SELECT button to navigate to the
desired top-level menu, pressing the UP or DOWN
button will enter the associated submenu. If no
PASSWORD was previously entered, submenu items are
view-only. If a valid PASSWORD was entered prior to
entering the submenu, editing the submenu items will be
allowed as described in the following sections.
After a submenu has been entered with the UP or DOWN
buttons, the SELECT button functions as an enter key to
select submenu items for modification and to confirm new
submenu item values after modification via the UP or
DOWN buttons.
After a submenu has been entered using the UP or
DOWN buttons, the UP/DOWN buttons become
activated to navigate the submenu and to modify
submenu item values when the value of interest is selected
by pressing the SELECT key.
The SELECT / ENTER button will continue functioning
as an ENTER button until a reset occurs, a power
up/down sequence occurs, or an escape sequence is
executed. Once any of the aforementioned occurs, the
SELECT button reverts to its original function of
navigating top-level menus.
4-6
P/N 0461391A
MENUS
SELECT
Button Pressed
Top Level Menu
1 Sec.
Submenu
Value
Top Level Menu
1 Sec.
Submenu
Value