English
– 35
SETTINGS
TUNING
Enter the 6 digit code to proceed to settings.
TUNING
SERVICE
1
3
Back
OK
2
4
Enter code
_ _ _ _ _ _
Hydraulics
Joystick
Mating Bluetooth®
radio modules
Back
Machine type
Units
Languages
Terminal Diagnostics
Hydraulics
The following components can be adjusted:
•
C1-C4, C1/C2
•
Rotation
•
Outriggers
•
Track L
•
Track R
•
Tool
•
Boom pressure
The selection "Reset system settings" resets all values to their
basic setting.
Ramp up/down
Ramp adjusts the acceleration of the drive.
A high up-value means slow acceleration.
A low up-value means quick acceleration.
A high down-value means slow braking.
A low down-value means quick braking.
Max-/min current
Max./min. current indicates the current interval that controls the
prop. valve. A too high minimum value means that the valve
opens rapidly. This might mean that it is not possible to employ
a function gently.
A low minimum value will increase the deadband of the control
lever around the central position.
A low maximum value means that the valve does not open
entirely and that the function cannot be run at maximum speed.
A high maximum value means that the valve’s maximum
opening position is achieved more rapidly. This will impair
resolution of the movement.
Boom pressure
The Boom pressure can be decreased from the maximum 200
bar to 150 bar. The pressure changes with 5 bar intervals.
Machine types
Indicates which machine type the remote control is linked to.
This setting must be made when updating the software or
replacing the control module etc. Press the selection key to
confirm the choice.
Languages
Setting for which language should be shown in the display.
Press the selection key to confirm the choice.
To return to the factory default language, english. Keep the
selection key for Work mode button while turning the main
switch until you see the main menu.
Joysticks
Settings for adjusting the function of the control levers.
Pos./Neg. Prog.
Pos. and Neg. Progression indicate the sensitivity of the
joystick. The higher the value the more sensitive the joysticks
are in their outer positions.
Deadband
Deadband indicates the position in which the joysticks start to
be activated. The higher the value the farther out from neutral
position that the joysticks are activated.
Mating Bluetooth®-radio modules
Used for remating the remote control with another machine.
During mating, the machine and the remote control must be
connected to each other by a cable.
Units
Setting for which units should be shown in the display. Press the
selection key to confirm the choice.
Terminal diagnostics
Test menu for the functions in the terminal (remote control).
Joysticks, potentionmeters and pushbutton can be tested.
SYSTEM INFORMATION
This shows the version of the software in the terminal and the
two control modules.
SERVICE
Summary of Contents for DXR300
Page 55: ...English 55 TECHNICAL DATA 4868 192 2368 93 5231 206 1818 72 ...
Page 58: ......
Page 59: ......
Page 60: ... z X16 6y 2013 09 25 z X16 6y 1156172 26 GB Original instructions ...