English
– 33
SETTINGS
EXTRA FUNCTIONS (optional)
The machine can be equipped with extra valves to make it capable of running more functions, such as a rotor and a tilt.
The value for oil pressure and oil flow can be adjusted from port A to B. Select which setting you would like to change with the
selection keys. Use the arrow keys to change the value.
At activation, the selected extra function (E1/E2) will appear in the symbol field at the bottom of the display. The symbol will remain
for as long as the function is active.
EXTERNAL TOOL
The machine can be used as a power source to operate external hydraulic tools.
The value for oil pressure and oil flow can be adjusted from port A to B. Select which setting you would like to change with the
selection keys. Use the arrow keys to change the value.
HOUR METER
The operating hours for the machine (the time when the motor is on) are saved in the control modules and can be read in the
terminal.
When the remote control (terminal) is connected to the machine, can the operating hours be read in online mode.
When the remote control (terminal) is disconnected to the machine the operating hours can be read in offline mode.
Extra function1
Oil pressure A-B
200 bar (30... 250 bar)
Extra function1
Oil pressure B-A
200 bar (30... 250 bar)
EXTERNAL TOOL
ON/OFF
SERVICE
Oil flow :
40 l/min (5...65 l/min)
Back
Oil pressure :
140 bar (30...250 bar)
xx bar
xx °C
EXTERNAL TOOL
Pressure: 140 bar
Back
Activate
Flow: 40 l/min
Adjust
xx bar
xx °C
EXTERNAL TOOL
HOUR METER