English
– 49
TROUBLESHOOTING
Communication error
Message on the display
Indication on the
machine
Effect on machine
functions
Cause
Possible action
No secondary control module found in
machine. Please check control modules
and CAN connection in machine.
No indication on
machine.
The PLC module do
not find any slave
module to
communicate with.
Restart the
machine. Check
supply and CAN
cables to the slave
module.
Machine type not selected. Enter
machine type menu and selectmachine
type for the current machine
No indication on
machine.
Communication
problem between
master module and
terminal.
Restart the
machine and the
terminal.
Selected machine type not supported by
terminal. This may affect machine type
specific functions
Communication error. Machine type could
not be uploaded to terminal. Please
restart terminal.
Communication error. List of available
machine types could not be uploaded to
terminal. Please try again
Communication error. Machine type may
not have been selected correctly in
machine. Machine type disabled in
terminal. Please make selection again.
Communication error. No new machine
type has been downloaded to machine.
Please make machine type selection
again.
Communication error. Parameter could
not be updated from machine. Please try
again.
Communication error. Parameter may not
have been correctly downloaded to
machine. Please try changing parameter
again.
Communication error. Warning
information could not be uploaded from
machine.
Communication error. Conflicting warning
information. Please restart machine.
Communication error. Terminal incapable
of uploading warning information. Please
restart terminal and machine.