2.3.2 Locking Data Flows on the Master Interface
Context
CAUTION
If data flows are locked on the master interface, they cannot be switched to the slave interface
automatically when the master interface fails. As a result, traffic is interrupted.
Do as follows on SwitchD shown in
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
smart-link group
group-id
The Smart Link group view is displayed.
Step 3
Run:
smart-link lock
Data flows are locked on the master interface.
----End
2.3.3 Locking Data Flows on the Slave Interface
Context
CAUTION
If data flows are locked on the slave interface, they cannot be switched to the master interface
automatically when the slave interface fails. As a result, traffic is interrupted.
Do as follows on SwitchD shown in
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
smart-link group
group-id
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
2 Smart Link and Monitor Link Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
26