Scenario
Configuration Scheme 1
Configuration Scheme 2
Fault
information
needs to be
transmitted
unidirection
ally between
Ethernet
CFM and an
interface.
Choose either of the following
commands according to the
transmission direction:
l
If fault information needs to be
transmitted from Ethernet CFM to
the interface, use the following
command:
oam-bind ingress cfm md ma
egress interface
l
If fault information needs to be
transmitted from the interface to
Ethernet CFM, use the following
command:
oam-bind ingress interface egress
cfm md ma trigger if-down
None
----End
4.13.3 Checking the Configuration
After the association between Ethernet CFM and an interface is successfully configured, you
can view the related association configuration in the OAM management view.
Prerequisite
All configurations of the association between Ethernet CFM and an interface are complete.
Procedure
Step 1
Run the
display this
command in the OAM management view to check whether Ethernet CFM
and an interface are successfully associated.
----End
Example
Run the
display this
command. You can view all associations between Ethernet CFM and
interfaces.
[Quidway-oam-mgr]
display this
#
oam-mgr
oam-bind ingress interface Ethernet0/0/1 egress cfm md md1 ma ma1 trigger if-down
oam-bind ingress cfm md md1 ma ma1 trigger if-down egress interface Ethernet0/0/2
#
return
4.14 Associating EFM OAM with Ethernet CFM
This section describes how to associate EFM OAM with Ethernet CFM.
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
4 Ethernet OAM Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
203