No.
Data
2
Names of MDs and MAs
3
SEP segment
4
Number of the interface added to the SEP segment
4.16.2 Configuring Association Between Ethernet CFM and SEP
Context
Do as follows on the device where association between Ethernet CFM and SEP needs to be
configured.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
oam-mgr
The OAM management view is displayed.
Step 3
Run:
oam-bind ingress cfm md
md-name
ma
ma-name
egress sep segment
segment-id
interface
interface-type interface-number
Association between Ethernet CFM and SEP is configured.
The interface specified by
interface
interface-type interface-number
must be added to the SEP
segment.
----End
4.16.3 Checking the Configuration
Prerequisite
The configurations of association between Ethernet CFM and SEP are complete.
Procedure
Step 1
Run the
display this
command in the OAM management view to check association between
Ethernet CFM and SEP.
[Quidway-oam-mgr]
display this
#
oam-mgr
oam-bind ingress cfm md md1 ma ma1 egress sep segment 1 interface Ethernet0/0/1
#
----End
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
4 Ethernet OAM Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
209