4.9.3 (Optional) Configuring the Anti-Jitter Time During Alarm
Restoration
By configuring the anti-jitter time during alarm restoration, you can suppress alarm flapping.
Context
Do as follows on each device:
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
cfm md
md-name
The MD view is displayed.
Step 3
Run:
ma
ma-name
The MA view is displayed.
Step 4
Run:
alarm finish time
time
The anti-jitter time during alarm restoration is configured.
NOTE
IEEE 802.1ag has two versions, that is, IEEE 802.1ag Draft 7 and IEEE Standard 802.1ag-2007. The
cfm
default md
command can be used only on the device complying with IEEE Standard 802.1ag-2007. Before
using the
cfm default md
command, you must use the cfm version command to set the IEEE 802.1ag
version to IEEE Standard 802.1ag-2007.
----End