The MD view is displayed.
Step 4
Run:
ma
ma-name
The MA view is displayed.
Step 5
Run:
map
vlan
vlan-id
The MA is bound to a VLAN.
----End
5.3.3 (Optional) Setting an Alarm Threshold for the One-way Frame
Delay Measurement
Context
Do as follows on the devices configured with MEPs:
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
cfm md
md-name
The MD view is displayed.
Step 3
Run:
ma
ma-name
The MA view is displayed.
Step 4
Run:
delay-measure one-way threshold
threshold-value
An alarm threshold is set for the two-way frame delay measurement.
----End
5.3.4 Configuring DM Frame Reception on a Remote MEP
The One-way frame delay measurement can work normally only when DM frame reception is
configured on a remote MEP.
Context
Do as follows on a remote MEP:
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
5 ITU-T Recommendation Y.1731 Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
265