On UPEA or PE-AGG, run the
display cfm remote-mep
command to check the status of
Ethernet CFM. You can find that Ethernet CFM is in Up state. Take the display on PE-AGG as
an example.
[PE-AGG]
display cfm remote-mep
The total number of RMEPs is : 2
--------------------------------------------------
MD Name : md1
Level : 0
MA Name : ma1
RMEP ID : 1
Vlan ID : 100
VSI Name : --
MAC : --
CCM Receive : enabled
Trigger-If-Down : disabled
CFM Status :
up
Alarm Status : RemoteAlarms
MD Name : md1
Level : 0
MA Name : ma2
RMEP ID : 3
Vlan ID : 100
VSI Name : --
MAC : --
CCM Receive : enabled
Trigger-If-Down : disabled
CFM Status :
up
Alarm Status : RemoteAlarms
Step 7
Configure the association between Ethernet CFM and interfaces.
# Configure PE-AGG.
[PE-AGG]
oam-mgr
[PE-AGG-oam-mgr]
oam-bind cfm md md1 ma ma1 trigger if-down interface ethernet
0/0/1
[PE-AGG-oam-mgr]
oam-bind cfm md md1 ma ma2 trigger if-down interface ethernet
0/0/2
[PE-AGG-oam-mgr]
quit
Step 8
Verify the configuration.
Shut down Eth 0/0/1 on UPEB and simulate fault on the link of Eth 0/0/1and run the
display
cfm remote-mep
command on PE-AGG to check the CFM status. The following information
is displayed:
[PE-AGG]
display cfm remote-mep
The total number of RMEPs is : 2
--------------------------------------------------
MD Name : md1
Level : 0
MA Name : ma1
RMEP ID : 1
Vlan ID : 100
VSI Name : --
MAC : --
CCM Receive : enabled
Trigger-If-Down : disabled
CFM Status :
down
Alarm Status : RemoteAlarms
MD Name : md1
Level : 0
MA Name : ma2
RMEP ID : 3
Vlan ID : 100