l
To create multiple MEPs in an MA, repeat Step 4.
l
To create MEPs in multiple MAs, repeat Step 3 and Step 4.
l
To create MEPs in multiple MDs, repeat Step 2 to Step 4.
4.8.8 Creating an RMEP
For other devices in the same MA, their MEPs are RMEPs for the local device. By configuring
an RMEP, you can perform connectivity fault detection between the local MEP and the RMEP
in one MA.
Context
If you need to detect the connectivity between a device and an RMEP, you need to create the
RMEP first.
Do as follows on the edge devices of an MA:
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
cfm md
md-name
The MD view is displayed.
Step 3
Run:
ma
ma-name
The MA view is displayed.
Step 4
Run:
remote-mep
mep-id
mep-id
[
mac
mac-address
]
An RMEP in the current MA is created.
----End
Follow-up Procedure
l
If you need to create multiple RMEPs in an MA, repeat Step 4.
l
If you need to create multiple RMEPs in multiple MAs, repeat Step 3 and Step 4.
l
If you need to create multiple RMEPs in multiple MDs, repeat Step 2 to Step 4.
4.8.9 (Optional) Setting the MIP Creation Rule
Context
Do as follows on each S3700 where Ethernet CFM needs to be configured.
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
4 Ethernet OAM Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.