![Huawei Quidway NetEngine80 Configuration Manual Download Page 215](http://html.mh-extra.com/html/huawei/quidway-netengine80/quidway-netengine80_configuration-manual_169456215.webp)
9 Telnet and SSH
Quidway NetEngine80
Configuration Guide - Basic Configurations
9-54
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 04 (2009-12-20)
STOC Cipher : aes128-cbc
CTOS Hmac : hmac-sha1-96
STOC Hmac : hmac-sha1-96
Kex : diffie-hellman-group1-sha1
Service Type : stelnet
Authentication Type : password
Session 2:
Conn : VTY 1
Version : 2.0
State : started
Username : [email protected]
Retry : 1
CTOS Cipher : aes128-cbc
STOC Cipher : aes128-cbc
CTOS Hmac : hmac-sha1-96
STOC Hmac : hmac-sha1-96
Kex : diffie-hellman-group1-sha1
Service Type : sftp
Authentication Type : password
----End
Configuration Files
#
sysname Quidway
#
radius-server template ssh
radius-server authentication 10.164.16.49 1812
#
rsa peer-public-key rsakey001
public-key-code begin
3047
0240
C4989BF0 416DA8F2 2675910D 7F2997E8 5573A35D 0163FD4A FAC39A6E 0F45F325
A4E3AA1D 54692B04 C6A28D3D C58DE2E8 E0D58D65 7A25CF92 A74D21F9 E917182B
0203
010001
public-key-code end
peer-public-key end
#
aaa
authentication-scheme test
authentication-mode radius
#
domain ssh.com
authentication-scheme test
radius-server ssh
#
#
sftp server enable
stelnet server enable
ssh user [email protected]
ssh user [email protected]
ssh user [email protected] authentication-type password