Security Commands
7.1 +CPWD–Modify PIN Password
7.1.1
Command Syntax
Command
Possible response(s)
+CPWD=<fac>,<oldpw
d>,<newpwd>
<CR><LF>OK<CR><LF>
In case of MS-related error:
<CR><LF>+CME ERROR: <err><CR><LF>
+CPWD=?
<CR><LF>+CPWD: (list of supported <fac>s),(list of
supported
<pwdlength>s)<CR><LF><CR><LF>OK<CR><LF>
In case of MS-related error:
<CR><LF>+CME ERROR: <err><CR><LF>
7.1.2
Description
The SET command is used to modify the equipment lock function (e.g. PIN).
The TEST command returns the supported device, and the maximum length of the
password corresponding to this equipment.
If the pin verification was enabled, you must input the valid pin before using this
command.
Note:
If you want to change password, the mode of CLCK must be 1.
7.1.3
Defined Values
<fac>: specify the object of operation of this command (only supporting SIM card, the
value is "SC").