5.3.3
Defined Values
<value>:
0: DSR line always is ON.
1: DSR line is ON when connected (reserved, not supported currently).
5.4 +ICF–Set Character Framing
5.4.1
Command Syntax
Command
Possible response(s)
+ICF[=<format>[,<parity>]]
<CR><LF>OK<CR><LF>
In case of error:
<CR><LF>ERROR<CR><LF>
+ICF?
<CR><LF>+ICF: <format>[,<parity>]<CR><LF>
<CR><LF>OK<CR><LF>
+ICF=?
<CR><LF>+ICF: (list of supported
<format>s),(list of supported
<parity>s)<CR><LF>
<CR><LF>OK<CR><LF>
5.4.2
Description
This extended-format compound parameter is used to determine the local serial port
start-stop (asynchronous) character framing that the DCE shall use while accepting
DTE command set and while transmitting information text and result codes to the DTE,
if this is not automatically determined (see +IPR).
We only support the setting AT+ICF=3, 3.
5.4.3
Defined Values
<format>: valid numeric value
3: 8Data 1Stop (default value)
<parity>: defined numeric value
0: Odd (reserved, not supported currently)
1: Even (reserved, not supported currently)
2: Mark (reserved, not supported currently)
3: Space (default value)