HUAWEI MU509 HSDPA LGA Module
AT Command Interface Specification
Short Message Service Commands
Issue 04 (2013-01-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
92
Field
Information
Comment
534E4E3A
TP-UD
send data
\x1A
ctrl-Z
If "+CSCA" has not set SCA, then
When sending the message, the <SCA> field must be completed, and the <SCA>
value can be obtained directly from the PDU packet.
AT+CMGS=17
>05a13109920081000B913109010054F3001804534E4E3A\x1A
PDU Format:
DATA:05a13109920081000B913109010054F3001804534E4E3A
Field
Information
Comment
05
SMSC address length
05
a1
TON
Domestic number
31099200
SMSC address
13902900
81
RP-MTI
RP-Message Type Indicator(send
SMS)
00
TP-MR
0
0B
DA Address length
Total 11 codes
91
DA-type
International code
3109010054F3 TP-DA
13901000453, last extra F is filled for
full information string.
00
TP-PID
GSM, point to point
18
TP-DCS
UCS2
04
TP-UDL
Send data length is 4
534E4E3A
TP-UD
send data
\x1A
ctrl-Z